Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why in a three pin plug the earth pin is thicker and longer
than the other pins?

Answer Posted / sarthak dalal

When we use electrical appliances with metal bodies, we require protection against possible electric shock. If there is a fault current (leakage) inside the appliance, the whole metal case becomes live. If you happen to touch it, a current will flow through you to the earth (ie. electric shock). Hence, to prevent electric shock, we need to ensure that the system is properly earthed (= 'grounded'). This way if you touch a faulty appliance, you don't get electrocuted!



So, why is the earth pin made bigger?

1. The earth pin on a plug is longer than the live and neutral pins. This means the earth pin is the first to connect and the last to disconnect.

When inserting the plug, the earth connection is made before the current carrying contacts of the plug become live.
When withdrawing the plug, the current carrying contacts shall separate before the earth connection is broken.
Thus, the earthing connection is always maintained to improve safety.

2. Many wall sockets have safety shutters (see image) on the live and neutral lines to prevent children from inserting conducting materials which may result in electric shock. Insertion of a longer (earth) pin helps in opening the shutters, facilitating the insertion of other two pins. These are called Earth-pin operated shutters.



3. Though it is impossible to insert the plug into the socket upside down, one may try to insert the plug top in a misaligned position (for e.g. trying to insert the earth pin into the phase socket with the other two pins further down out of the socket). Hence, the earth pin is made thicker so that even by mistake it cannot be inserted into the live or neutral hole of the socket. This prevents earth pin from establishing an electrical contact with the live terminal.

As you can see, every effort is taken to protect you from electric shock.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are the advantages and disadvantages of oil filled cables over XLPE cables

19337


what is the voltage regulation for unity and zero power factor?

2256


How will be the single line diagram of series trip HT breaker? how it works?

2549


what is the function of impulse relay

2471


What is meant by harmonic distortion?

1062


1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.

1747


Why the arms of delta in a delta-wye power transmission system are kept constant??

1820


What is center gravity load in substation?

2366


What are the basic & Majour problems in UPS ?

2076


Can 33kva/415v transformer be run underground? If the answer is yes why and if the answer is no why?

1524


Distinguish between nuclear power station with thermal power station for initial cost, starting period, cleanliness, and transportation of fuel

1978


Explain the purpose of inductor in an electric circuit?

1074


What is Traction? 1KVA Alternator, How much urrent taken?

2053


plz tell me,ht and lt panel terminals in substations explain beiefly

2879


i have 3500 amp load and select current transformer and perches.how i calculate .please understand

2109