We have 11kV/110V three phase indoor potential transformer in 66/11kV Sub-station, where the failure of PT is frequently happening and the rating of the PT is 0.2 class accuracy, with primary star and seconday (two cores) star connected.
Some experts has suggested to not to connect the PT Primary neutral to the ground because when transformer neutal NCT connection is loose; the faulty current will flow through the PT primary neutral, resulting into failure of PT.
My question is: Is it necessary to remove the primary neutral connection of the PT from ground? if not, what would be the reason for failure of PT.
Please guide me.
Answer Posted / k.prakashchandra
Intimate whether PT fails whenever there is an earth fault and which winding fails
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is mean by dual digital protection in the relay field?
i am electrical and elctronics engg passed out in 2009 want to attend for reliance placements.plz send me apttitude ,technical and hr question answers to my mail plz. my mail id-kat.bindas@gmail.com
Do you know what is dry-out test in x'mer
in control scheme dc logic wiring commonly using negative loop,what is the reason?if we use positive looping what will happen?
Brushes are placed at magnetically neutral axis,when brushes reach that point,the armature conductor gets shorted,but it can be seen that the dc supply is also shorted,wont that get damage? help me plz
Difference between HRG and NGR. Are they both the same thing
what is plunger and what's the use of it in motor alignment?
how the speed of the gets motor regulated. does it draw the same current on the all speed level.
why are the maintaine power factor and how can this control and this is how work.
What is block diagram?
If there is major % of Voltage harmonics in the system, how can it be control or reduced?
Do you need any help with FEWA Electrical Supervisor exams?
What happens to voltage when current is zero?
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
derive DC RMS value for half wave rectifier?