Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is open star connection or open delta.

Answer Posted / anayat

Open delta is usually three transformers connected in parallel in such a way that if any one of the transformers operates inefficiently the rest two will mantain the load ....or in short if one of the three transformers ooerating in parallel is disconnected the arrangmnt obtained is called an open delta connection....

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to calculate singlephase motor efficiency?

2230


How to calibrate or test an LT Air Circuit breaker 440 volts, 35 KA, 800 Amps ?

1913


working principle a.v.r. ?

2402


I AM FROM ELECTRICAL ENGINEERING ? I AM ASPIRING FOR "BHEL".HOW I HAVE TO PREPARE .ON WHICH TOPICS TO BE CONCENTRATE MORE.PLEASE GIVE FULL DETAILS OF WRITTEN EXAM.

2115


how we test a 3 phase motor on single phase supply....? HOW WE RUN A 3 PHASE MOTOR ON SNIGLE PHASE. supply for testing..? how we verify of a 3 phase motors 6 wire & name thame a1/a2/a3..b1/b2/b3 and c1/c2/c3 for connecting star delta starter ........i have only 1 phase supply ? help forum..........

5183


we have an energy meter in a capacitor bank panel, So should we consider it's readings as energy consumption on daily basis. (when capacitor bank doesn't have any energy losses)

2402


how we findout a ignater is faulty or not?

2100


What are n circles?

1082


primery try cell?

2191


What the main causes of transient interruptions on Over-Head Distribution Lines?

2111


I HAVE A INCOMING 100A MCCB TPN 25KA, CABLE LENGHT OF 80M 70MM CABLE SIZE FROM MAIN SUBBOARD TO NEW DB.BASE ON THE FAULT LEVEL SETTING OF 45KA.I WOULD LIKE TO FIND OUT 25KA ENOUGH KA. APPRECIATE IF SOMEBODY CAN ASSIST ME WITH FORMULA FOR THIS. FRM: JEFF

4026


why we use the 100% and 95% stator earth fault protection for the synchronus generator ?

2302


TRANSFORMERS WITH DC SUPPLY

2074


what is the ckt diagram of a tubelight and is it the simplest ckt of electrical engineering and also the component?

2377


what is meant by motor startup supervision & motor load jam protection ?

6002