Answer Posted / bhavesh jaiswal
A)In three Phase, Make star connection,With resistance in each phase. Show in fig.
RED
| RED;Y;B are Phase
R R Resistance
__R____|......N N Neutral
Y |
R
|
B
For Single Phase, Neutral is taken from transformer.
For Two Phase
RED
| RED;Y are Phase
R R Resistance
Y__R____|......N N Neutral
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
why dc is used in control circuit for mv & hv switchgear instead of ac
What is the basis for framing the rules of block diagram reduction technique?
How is the speed of a DC shunt motor related to the armature current?
A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.
what is KA rating and how can we choose switchgears on applications
how does high earth to neutral voltage affects electronic circuit?
What is the minimum distance to be maintained in between HT panel and LT panel and Instrument panel as per IEC and NEC standards?
Briefing the effects of ASR and ACR of a double closed-loop speed regulating system.
sir please send me previous year questions of jspl of electrical section through which i could prepare myself fpr the test.
What is the simplest formula to calculate the rotor diameter of a synchronous generator?
I am having a 1500 KVA transformer whose secondary current is 2086A and my connected load is 1000 KVA, I am having 400 KVAR APFCR for PF improvement what ratio of CT should i install in LT EB Bus to get optimum PF improvement?
how flow current in 220 kv line to line
Can any answer me ,What will be the range of C.T coil for L&T energy meter EM301 used for 180 kva DG set
give me applications of sequence bridges . (used in 3 phase un balanced systems)