Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

for which type of applications gas chromatography is used?

Answer Posted / nagaraja

for Volatile compounds and Vapourizable organic compounds (Thermally stable compounds) is used for GC analysis.Resolution depends upon solvents elution order.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

which are the diffrent batches in the pharmaceuticals?

820


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

799


why we are using benzene, anyline in acetic anhdride assay titration method?

2117


some product having water content method with pyridine and ethylene glycol mixture instead of methanol? how they are selecting and methanol is not suitable solvent how ?

2656


in DMF having extra impurities and in api COA also having extra imp than USP or BP product then how require to proceed?

840


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2685


if you get peak in blank then what require to do?

977


Why potassium dichromate is used in calibration of uv?

1990


what is partion and column chromatography

2393


what is mean by dissolution biowaiver study?

936


How do we fix the sample concentaryion in hplc method development?

1144


In IR spectra, generally a molecule vibrates without apply emr or ir light?

1982


why require to add enzymes in capsules dissolution only? is it require to tablet also?

680


CAN WE DETERMINE THE PEAK PURITY IN GAS CHROMATOGRAPHY ANALYSIS?

1213


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1600