Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Can i convert 230v ac to 24v dc by using a relay?Instead of
Smps is it possible?
What is relay logic in plc ??
How it works?

Answer Posted / sajjad khan

in PLC relay use only switching device'
i think using rectification convert 230 AC to 24 VDC
use 105400 volt PF and diodes and filter copacitor 220uf35 volt copacitor and Ziner Diode 24 volt 2 watt.
it's circuite is very simple and small.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In my company plc based winders are operated. one day there was a data transmission failure alarm shown on pc. as per sir instruction we have reset master plc but winders were not triped and alarm gone. so what master plc do?

1925


Good evening all I need a small favour regarding reliance paper i wanna probable sample papers(e&i) of reliance. if any of u have any idea about dis then plz mail me back.i belongs to electronics and instrumentation engg.so i need e&i papers. thanking u....

2134


Why even multiple power supplu r used in instrumentation system?

5066


When doing a liquid seal on a differential flow transmitter , most of the time the sealing liquid will be heavier then the process fluid. For wich application will the sealing liquid be lighter than the process fluid if transmitter is mounted below the process line.

1863


how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?

5731


what would be the minimum flow rate that we can measure on rotameter..?

2144


SOME OF YOUR QUESTIONS ARE NOT MAKING ANY SENSE SO TRY AND PUT IN A LITTLE BIT MORE EFFORT BEFORE YOU POST A QUESTION. WE WILL ONLY HELP THOSE WHO WE CAN SEE ARE TRYING TO HELP THEMSELVES.

2428


What should be the main consideration while starting the Rotating compressor when we dont know the cut in and the cut off pressure setting of the pressure switch

2264


where uses EXe /EXd/Exo/Exn/Exp/Exq/EXia

9988


Can anyone convert a 5/2 way or 3/2 way valve into an ISO valve?

987


Explain the combusion chamber

2072


how to connect transmitter measuring sulfur process? 1-by using long impulse line or 2- by using coated short impulse line

2158


what is RTV function in in process control?

3171


Turbidity analyzer working principle ?

1833


What is cut off relay? And why use in PLC and DCS?

1414