1.what is the reason for transformer and lightning arrester
blast in 33kv system
Answer Posted / rajib kumar chowdhury
If Line voltage increase for line load suddenly off than it can blast [without rainy day].
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
what is restricted earth fault explain in details
How do you consider that you can improve and what assistance do you need to achieve this
what is the meaning of SST300 V56A in SIEMENS turbine
some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor
Why superheated are started before I'd and rd fan?
What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon
what is the difference between compensated & normal drum level in boiler drum?
how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?
How to calculate power press toneage
procedure of how to generate power in solar plant.
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?
dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job
Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.