Question 37 - Calculate the bubble temperature T at P = 85-kPa for a binary liquid with x(1) = 0.4. The liquid solution is ideal. The saturation pressures are Psat(1) = exp [ 14.3 - 2945 / (T + 224) ], Psat(2) = exp [ 14.2 - 2943 / (T + 209) ] where T is in degree Celsius. Please take note that x(1) + x(2) = 1. Please take note that y(1) + y(2) = 1, y(1) = [ x(1) * Psat(1) ] / P, y(2) = [ x(2) * Psat(2) ] / P, * is multiplication. P is in kPa.
Answer Posted / kang chuen tat (malaysia - pen
Answer 37 - By trial and error, T = 84.37 degree Celsius. Excel program may be used, either by Solver or Goal Seek. Overall equation : y(1) + y(2) = 1 = { 0.4 exp [ 14.3 - 2945 / (T + 224) ] + 0.6 exp [ 14.2 - 2943 / (T + 209) ] } / 85. Solve the equation by computer iteration with one unknown will produce T = 84.37 degree Celsius. Let x(2) = 1 - x(1) = 1 - 0.4 = 0.6, P = 85. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is the ignititon temprecher of Diesel,Petrol&Carosion oil.
Explain some good strategies for curing tube vibration in shell and tube exchangers?
In a crusher where is the energy provided to it is used up for?
Please colleagues I need to choice a proper hopper shape for a Fertilizer bulk blender flowing throut a high humidity raw material like zeolite, so we are in doubt whether use squard or rectangular hopper shape to avoid the so call voul effect that can create obstruction
At what temperature does water have maximum density?
We are having proplem with the persperation smell in ETT/ECHO room in our cardiac hospital.The 2 Ton of AC is not conditioning the environment. We have to use exhaust fan to through out of the room bad air. Could anyone suggest how to coup with this effectively using chemical engineering. Any permanent solution to neutralise the bad smell.The Air freshners are not doing enough instead making a bad odour.
In a Furnace arch pressure is more than Hearth pressure,then how flue gas travels to stack
What is higher heating value and lower heating value? Is it positive or negative?
Who built the first production scale pla (polylactic acid) facility?
What steps can be taken to avoid stress corrosion cracking (SCC) in steel vessels used for storing anhydrous ammonia?
Difference between Synthetic foaming agents V/S Protien based foaming agent?
What factors go into designing the vapor space of kettle type reboiler?
What are the different characteristics that can affect the flow of bulk solids and how?
design calculations for reactor
Where the Induced draft, forced draft & balanced draft furnace are to be used? Selection of furnaces are based on which criteria?