Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is discriminating media? How can u justify/select that
which media (pH etc...)is suitable for your dissolution study
of your compound?

Answer Posted / pramod

Discriminating media is a media which shows variation in results with different formulations.I.e.Chang in excipients,excipients composition etc

Is This Answer Correct ?    11 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is shaking level in GC?

792


if you have given a blank water how you analyse by general analytical techniques?

2032


why does used dry caffien in HPLC calibration?

2032


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

773


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4074


Why use only methanol,used determinationof moisture content not use other solvents

1408


why digestion require in icpms?

774


in dissolution why pool sample needed? in which type of drug pool sample need?

3180


Related substance method equivalency on control sample or spiked sample?

771


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1597


Loss of linearity in tkn analysis, possible reasons?

1319


why lactose has less charges when packed in steel containers when compared with packing of lactose in polyamide material?

2299


in stress study if your api not soluble in hcl naoh h2o2 then what require to do?

840


if you given one product then which tests you will perform?

709


is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth

2174