Question 36 - For a mixture of benzene (B), toluene (T) and xylene (X), the equation applies where x for B, T and X will sum up to 1. The equation of x for each component is x = (L / V + 1) (F) / (L / V + K). The data of F for each component are : 0.5 for B, 0.35 for T, 0.15 for X. The data of K for each component are : 1.98 for B, 0.76 for T, 0.24 for X. When x for B + x for T + x for X = 1, find the values of (a) L / V; (b) x for each component of B, T, X respectively. You may use Excel program - Data : What-If-Analysis for Goal Seek to perform the iterative calculations.
Answer Posted / kang chuen tat (malaysia - pen
Answer 36 - By using Excel program, L / V = 0.654. The data of x are : 0.31 for B, 0.41 for T, 0.28 for X. You may bring your own calculator on laptop or phone with Excel program to assist the trial and error. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What are the different ways in which solids can be blended?
Explain the difference between cfm (cubic feet per minute) and scfm (standard cubic feet per minute)?
How is waste heat boilers categorized?
what is load and what are the types of load?
What compounds are responsible for the odors that come from wastewater treatment plants?
How can you estimate a gas flow based on two pressure measurements?
At what temperature does water have maximum density?
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
How can arsenic be removed from aqueous waste streams?
What are the effects of oils on the properties of Polyolefins?
How can you quickly estimate the horsepower of a pump?
How fouling effected the heat transfer rate?
Explain why is post-weld heat treatment (stress relieving) sometimes necessary for welded vessels?
Explain what are some typical applications for glass-lined reactors?
Dear sir/madam I am in final year BE chemical engineering.Which companies i can apply .Please guide me.It is very helpful for me