what is the difference between venturi and orifice meters?
Answer Posted / seenu
In venturimetre there is uniform flow of liquid because of throat ,but where as in case of orifice metre there is no uniform flow of liquid .because plates can be changed upon discarge amount.
| Is This Answer Correct ? | 9 Yes | 3 No |
Post New Answer View All Answers
what are the diff. in servo and regulatory control?
(1) In turbine, what does term CDP, NI, NH, HSSOC, means. (2) What is the purpose of LO overhead tank in turbines.(3) An equipment is certified for EEX, IA, IIC,T6, what do you under stand by this.(4) what is SURGE, and how it is prevented, what is the purpose of bypass valve across AS valve.(5) Give 2 application of quartz crystal used for process parameter measurement.(6) what is meant by cold float of compressor shaft. (7) state four different types of flow measurement. For gas flow measurement mmscfd is the common unit. Expand the unit and specify significance of word S in the unit.(8) what is meant by Gap voltage, in vibration measurement. Normally how much Gap voltage is set and state the reason.(9) what will the new flow factor if D/P transmitter is Re-Ranged from 25” wc to 50” wc.(10) what is the usage of QDV & Volume booster.
give some question relative instrument fitter?
How to Calibrate Coriolis Flow transmitter in field
basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......
what is function of sensor, and how is it work , explain with difination
flow transmitter formula?
on interface level transmitter model(RTG3302-EMERSON) What is threshold valve how can we select correct threshold value T1,T2,T3,T4 When interface water & hydro carbon
What is surge and how is it prevented, what is the purpose of bypass valve across AS valve.
What is 3 selection available when configure the burnout protection for controller
We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.
Manipulation of dead wt. tester double piston type.
How to calibrate Toxic gas detector?
Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?
what are the definitions of input, output, command & signal according to instruments controlled by PLC using DCS System?