Induction motor & transformer both has magnetic core,then why induction motor is a inductive load & transformer not???
Answer Posted / bharat
Transformer consume very small power its efficiency is more than 98%. Means it is not a load it is only transforms power i.e. step up or step down voltage. However it may not be denied that whatever load it has is an inductive load.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
What safety precaution are to be taken for avoiding electric hazards ?
on a three-winding transformer relationship delta-delta-star, on third winding why the relationship is a star? what are the advantages and disadvantages? Thank you and please help
Why AC current leads voltage in capacitor and how?
what is a power factor?
Iwould like to know barc interview questions
Whether amorphous core transformer is available in India?.If available then up to what rating of voltage and KVA?.
what is meant by LCR meter? where its useful ?
DC transmission
SUTIABLE FOR ohm's law super conductor
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
Explain the method to keep noises low in a control system?
How to find out damper winding failure for synchronous machine?
What is tranformer differtial?
why the NGR (neutral grounding resistor) always OFF during DG off?