If two generator running parallel, at that condition both ngr
Taken in line or taken any one ngr, but why any one or both
Ngr in line?
Ngr is use for which purpose?

Answer Posted / harkamal singh

NGR Neutral ground resistance

Ngr panel is use allow to minimum range of unbalance current of Electrical alternators and add extra resistance in series of neutral link.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

can anyone give an idea about dia calculation in cold rolling mill

1185


What are the basic elements used for modeling mechanical rotational system?

625


in general it is observed in power stations, the tertiary winding is used in higher rating Y-Y auto transformer but not in Y-Y power transformer. is the tertiary winding is compulsory then why it is not using in power transformer 

1302


WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.

1446


How to convert 2 phase to 3 phase electricpower in induction moter?

1684






what do u understand about FACTS? how they are useful?

1542


I want to know how to calculate the size of electricity cable in building?

1540


We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?

1641


how we calculate the withstansing current capacity of wires&cables?

1493


Please tell me in DETAIL about the following 3 types of fuses or recommend me a good power system protection book or a website link ? 1.Dropout Fuse 2.Striker Fuse 3.Empulsive fuse (not sure if its impulsive or explosion fuse , sorry)

1680


What is the gross weight to copper ratio in slip ring induction motor of 4000 HP,6.6 kv, 372amp, 992 rpm GE motor.

1917


please give me all the Alarm .Trip ,Safety Relays & Conditions of UPS Systems mail me on ashokbabunhce@gmail.com

1375


testing of Vector Group – YNaoD II

2464


What is installed in PAC that is control the humidity

1059


What is meant by reactance voltage?

637