Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I am a instrument technician. recently i attend interview and face one of question for DP transmitter ,the client asking about the calibration of DP transmitter ,am answer the calibration procedure, they will ask one more question. why open LP side in atmosphere? i did not answer that question. so please help me and explain the particular question. Dear firends waiting for your valuable replay

Answer Posted / ahmed

Calibration coefficient we titration differential pressure device through the injection amount of pressure in the high side and at the same time the low side open to atmospheric pressure, because pressure air fixed and unchanging and the device works on the difference between Aldgate if the equation realized there atmospheric pressure fixed and your controlled pressure from here the differential pressure is measured

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Where is wet leg is used?

1061


Sir,I am going to sit for IOCL written test exam. recently.Can anyone tell me the name of 'Objective type Question Book on Instrumentation Engineering ' which will help me. Pl. mail to bidyut_71@rediffmail.com / bidyut.saha2008@indiatimes.com / bidyut.saha09@yahoo.in

2072


Draw bode plot of any transfer function. Why is plotting bode necessary?

2513


how to calibrate corollaries (Mass flow meter)?

2169


how can we tune a PID. If it is by zeiger nichols method..please explain briefly with help of an example.

2476


If P will increase then what will happen with PID?

6063


Instrumentation Safe Guarding test. How to determine the interval time of the test. eg:Halfyearly,Every year,Every three years etc.

2118


Difference between ultra sonic flow meter

1993


what are the values of fuel flow rate in various places in boiler.

1726


What is the difference between uv and ir scanners? and what is the workig principle of both

2371


What is the reason PT speed not incresed in gas turbine?

2407


what is instrument philosophy

2263


How to Calibrate Coriolis Flow transmitter in field

1266


How to regulate the flow of Air in 4" line, with max flow of 330 nm3/hr and Pressure of 0.5 bar? please suggest the type of instrument required.

1508


what are the steps I have to deal with?

2245