Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the main difference between power transformer and
Distribution transformer?

Answer Posted / pushparaj

Distribution Transformer are Output LT supply and power transformer are HT/HT step Down/Up.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why the electrolyte level in lead acid battery is maintained 2.5 cms above electrodes?

1810


l&t switch FN 63 handle position can we change

2507


what are the preventive maintanance actions taken for air circuit breaker? please answer me

1981


sir& friends i want the collection of recent quetions asked in interview of top most companies please send me on my email san.jsr@hotmail.com

1745


Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example?

2139


How to confirm the Phase shifting Transformer VECTOR GROUP relation , as below ZNy11.45d10.45-ZNYy0.15d11.15

3209


what should be the acceptrd value of winding resistance for 2.5MVA transformer

2263


Draw the line diagram of diffretial relay connected to transformer?

2381


Can clean earth cable be considered as low current cable

1920


what is current check gurd relay?

2535


how to discharge 3 phase power factor correction capacitors

2404


why connecting surge unit in contactor coil

1824


why the active power flow of some line is increased when the active power of out is cut ?

1988


bsec exam syllabus (mis)

1220


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

741