in three phase it represented by R-Y-B.what is full form of
R-Y-B.
Answer Posted / sunthannagesh@gmail.com
R=red
Y=yello
B=blue
thise is as per international beuro of electricfication IBE this is a standerd code
| Is This Answer Correct ? | 13 Yes | 2 No |
Post New Answer View All Answers
Define branch?
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
What is the different between conventional MCC and intelligent MCC? Common controller or controller for each bucket
What is star-delta transformer?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
If 24 KVA AVR having Input voltage 200-400v, Output voltage 415+-1%, what will be the voltage if Load is 13A.
Is there any question in the name of Static Switch in UPS??
how is find out kwh step by step
what kind of technical test that i need to learn because i have an interview tomorrow.. please someone help me..
why cable i burning without tripping. how can protect led street lights
how to measure earth resistance of a substation
Write the force balance equation of m ideal mass element.
What difference between ref protection and differential protection ?
HOW WORK HEAT PLATE EXCHANGER
what is under coal gassification?