What is the function of trip neutral close switch?
Answer Posted / sunil kumar
TNC switch is a three position switch. when it is
in close position it will put the circuit breaker in
operation by energizing the closing coil and when it is in
trip position it will trip the circuit by energize the trip
coil in circuit breaker. But the switch After energize the coil it is going on in neutral position Automatically.
Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
hello friends this is krunal here.. i have applied for he officer train in hpcl electrical stream.. any one who have applied before for electrical stream please help me out.. post ur reply to my mail id: krunal_airforce@yahoo.com.. any tips, old questions for paper or any help will do.. plz help me.. your faithfully, Krunal Darji
PLZ EXPLIN ABOUT CLASS PS CLASS CT .WHY THEY R DESINED AND FOR WHAT PURPOSE?WHY OTHER CT CANT BE USED AS PS CLASS CT? EXPLAIN IN SIMPLE LAUNGAGE IF POSSIBLE PLZ GIVE CIRCIT DIAGRAM?EMAIL-RAJ_SINGH_0376@SIFY.COM
can we use NPT glands in LT panel
can i use 4 number of circuit breaker as single phase manual change over switch? if yes then how plz also send ckt diagram at nazimzamurad@gmail.com
I would like to know that the fault curretn at base load and at 10% generation will be same? Fault level of BUS remain same with different generation?
pls tel me the electric train traction motors name plate details like rpm,torue,voltage,amps,watts..ect..
What happens if i apply 500V to 440V rotary Switch ?
i need to now what will be the cable size to the following load, transformer to distribution panel distance 110m, load 1000kw, voltage 400v, pf 0.85, permissible voltage drop 2.0%, overhead line, atmospheric temperature 35 degree c.
how to interlock 3 incomer-ACB,1 buscoupler ACB,... pls answer this question and if possible send me the ckt diagram..haifriends2910@gmail.com
What is the normal phase difference between the voltage and the no-load current in a transformer?
how much GROUND & NEUTRAL VOLT maintain in data center.
What effect does a very low impedance have on the Voltage regulation? On the short-circuit current?
What the difference between three phase contactor (coil 110vac) & three phase SSR (control voltage 110Vac)? May I use contactor in place of SSR?
what is mind in cable
for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?