What is cogging and crawling phenomenon in motor.

Answer Posted / upenderb

Cogging:the tendency of locking of rotor with the stator poles when they have equal slots or any similarities between the slots is called cogging
Crawling:the tendency of rotor to rotate at a low speed equal to the seventh space harmonic i.e Ns/7 if there are considerable amount of harmonics is called crawling

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Stator of 3-phase IM has 3 slots per pole per phase. If supply frequency is 50 Hz, calculate the speed of rotating stator flux A 1000 rpm B 500 rpm C 1500 rpm D 1440 rpm

1686


What is a commutator?

616


two phases with neutral supply can be taken in 3C X 10 sq.mm cable .

1008


sir i want previous entrance exam papers for written test

1698


What is maximum power transfer theorem?

651






If 22 KV HT line, Current transformer is 25/5 then how to calculate multiplying factor.

617


What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?

1257


what is per unit calculation?looking for simple and strong explanation thk u

2442


There is any especial requirement for motor to drive through with VFD?

2180


What is meant by impedance? difference between high & low impedance ?

1567


Hi friends, i m electrical engineer i want a cdr for migration purpose so anybody have information about this then send me on jayesh_ee88@yahoo.com.please try to me

1436


i wasted one year for the job after completed my btech what can i say about 1year time in interview

1600


I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.

1381


if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.

1148


it is possible to measurement of tension of slipring induction motor(SRIM)carbon brushes, any maesuring instruments are available in the markets.

1500