ORA-14120: incompletely specified partition bound for a DATE
column
Answer Posted / guest
Cause: An attempt was made to use a date expression whose
format does not fully (i.e. day, month, and year (including
century)) specify a date as a partition bound for a DATE
column. The format may have been specified explicitly (using
TO_DATE() function) or implicitly (NLS_DATE_FORMAT).
Action: Ensure that date format used in a partition bound
for a DATE column supports complete specification of a date
(i.e. day, month, and year (including century)). If
NLS_DATE_FORMAT does not support complete (i.e. including
the century) specification of the year, use TO_DATE() (e.g.
TO_DATE('01-01-1999', 'MM-DD-YYYY') to fully express the
desired date.
Please add more information about this Error
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
[ERROR] [main 11:01:20] (JCLLoggerAdapter.java:error:454) Unsuccessful: alter table user.CEN_USER_MASTER add constraint FKF4EDEDC3D0BAAE75 foreign key (ROLE_ID) references user.CEN_ROLE_MASTER [ERROR] [main 11:01:20] (JCLLoggerAdapter.java:error:454) ORA-02275: such a referential constraint already exists in the table
ORA-26079: file "string" is not part of table string.string
ORA-26027: unique index string.string partition string initially in unusable state
IMP-00070: Lob definitions in dump file are inconsistent with database.
When i am connect database through toad,one error occured. ORA-12514: TNS:listener does not currently know of service requested in connect descriptor. plz help me thanks advance.............
invalid quantity specification negative quantity are not allowed for this item please check this item definition quantity
IMP-00063: Warning: Skipping table "string"."string" because object type "string"."string" cannot be created or has different identifier
ORA-26032: index string.string loading aborted after string keys
ORA-26030: index string.string had string partitions made unusable due to:
NZE-28868: Peer certificate chain check failed.
ORA-16627: No standby databases support the overall protection mode.
if the lengths of two wires are same and the area of cross sections is 4:7 then what will be the ratio of current passing through these wires
ORA-26076: cannot set or reset value after direct path structure is allocated
How to resolve QSM-01108 error. I have no OR conditions in my query, but do have 9 IN conditions. The error says the max limit is 2 while I have 257 number of disjuncts. However, if I remove even a single IN condition, the query is rewritten. I cannot change my query. How can I resolve this issue?
IMP-00060: Warning: Skipping table "string"."string" because object type "string"."string" does not exist or has different identifier