Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we inject sample TWICE in ASSAY by HPLC analysis but in RS once?

Answer Posted / raveendra kumar

we injecting the two injections from one sample preparation to know the precision and reputability of the analyte.
(During real analytical practices we inject only two injection in single assay analysis. So accuracy of single injection is question.)

Is This Answer Correct ?    13 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in api coa contains only process impurities and in product coa contains degradation impurities?

701


mode of absorption in alimentary canal?

2389


How to know the estimated LOQ concentration in ppm

1213


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3540


if content uniformity passing but dissolution varrying then what is next step?

877


Tell me about analytical method validation in QC

6177


why require the ph, buffer during hplc mobile phase?

861


how decide the clining method and cleaning method validation require for this perticular products?

755


What is the main difference between ODS1 and ODS2 Hplc column.

5217


In which situation we require to analytical method validation of excipient?

787


How do we fix the sample concentaryion in hplc method development?

1140


We use hicrome 10 cxs column in hplc analysis....pls tell me.. what is the meaning of 10 cxs?

1717


what are the guidelines for analytical method validations?

1100


How do we get end points and how many end points are possible for citric acid and di-acid not theorotically answer should be given practically.

2584


What are the primary considerations in extractables and Leachables ?

2275