waht is difference between pressure transmitter and
transuducer
Answer Posted / vinodkumar
A transducer is a device which converts one form of energy into another. But a transmitter is a device which is composed of a series of transducing stages to give output as industrial standard signals. The industrial standard signals are pneumatic (3 - 15psig), electrical (4 - 20 mA). there are three types of transmitters. Pneumatic transmitter, Analog Transmitter and Digital Transmitter
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is the input of digital counter during the the calibration time?
There are two chlorination tonners both are connected to two pressure swithes and the pressure switch is connected to SOV which operates the valve to changeover the tonner selection i.e if pressure one tonner goes low the other tonner should come in line if it is inautomatic selection design a circuit using relays ?
Why plc require in analog input 4-20amp & 0-10 volt?
Draw a simple circuit for a well head control panel used to protect the well against fire, leak, blockage, ESD, & controls the operation of one downhole & one surface safety valve. Explain the operation and controls
please any body have most important data for study for saudi aramco test of instrument QC thanks email shahnaveedullah@gmail.com
What are primary elements of measuring pressure?
How hart protocol can be connected with control valves?
Explain the key components of control loop?
Why do we floating DC in DC system.
What is the use of control cable?
How can we use feedback signal frm rtd for monitoring and in dcs for controlling ,then which type of rtd is sutaible 2 , 3,4wire and why ?
Sir,I am going to sit for IOCL written test exam. recently.Can anyone tell me the name of 'Objective type Question Book on Instrumentation Engineering ' which will help me. Pl. mail to bidyut_71@rediffmail.com / bidyut.saha2008@indiatimes.com / bidyut.saha09@yahoo.in
What are the application of bernoulli’s theorem?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
in differential pressure transmitter,min&max pressure range for hp&lp