Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are the advantages and benefits of using PLCs to automate
a section of a plant?

Answer Posted / cae

And also it can work at very hazardous places with great accuracy where humans can not work. it operates at low voltage levels like 12v or 24v DC, so that losses are very less. there is a chance of modify the ladder logic more frequently as per the process needs.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Meaning of the following a. IOP- Manimum; b. IOP- Maximu,;

2253


If i have 4 Allen Bradely make RS logix 5000 PLC and for viewing that we are using 4 RS view SCADA for 4 different packages. Now, I will want to view two packages on only one SCADA. Then how i will do it?

2435


in valve is constructed as per SME B 16.34, then which standard is used for fire testing of valve?.

2066


while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?

1970


If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?

1536


Why flow/pressure transmitter before control valve?

1615


How many ohms are required for proper earthing?

1132


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1517


Do you have reference list?

1890


State bernoulli’s application.

1197


what is the procedure for auto tune in masoneialn 12300 series displacer type transmitter?

1685


How process line mpm calculation is done?

1473


what is o2 analyzer and how it measured ,what is the role of this analyzer in cfbc boiler...

2052


please send data bank of quetions answers on analytical instrumentation.

1931


How to calibrate Magnetic flow Transmitter in Field

1313