Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why do we use 500ppb sucrose and 500ppb 1,4 benzoquinone in
TOC calibration?

Answer Posted / ravindra gore

Sucrose is easily oxidized and 1,4 Benzoquinone is not easily oxidized

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1801


Why use only methanol,used determinationof moisture content not use other solvents

1396


For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?

2305


What is diffrence between extractable volume and deliverable volume? Answer pls

4554


is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth

2165


if peak get problamatic then what require to do?

792


what is impurity profile. how to interpret this impurity profile to a drug product or drug substance.

2624


sop of a uv visible spectrophotometer double beam elico model

5904


While performing TOC sst analysis Zero shift disabled & sample analysis zero shift enabled why?

2852


in which situation require to use paddle and basket?

729


pharma industries oriented

2227


what is diffrence between specificity and selecivity?

758


How we can identify process related and degradation impurity in single method with short period?

806


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

912


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3532