Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In UV calibration we use Holmium perchlorate solution made in 1.4M perchloric acid The question is that 1.4 M perchloric acid we make is it in water or glacial acetic acid?

Answer Posted / deepak dongare

Water

Is This Answer Correct ?    18 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A ha tc is actual defination of retention time?

1552


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1909


is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth

2104


What are usp limits for theoritical plats,resoution,tailing factor,peak to valley ratio

1850


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3487


why xterra column require to use at higher ph?

868


Why dissolution test is not performed in all of the products

2482


using gradient pressure in gas chromatography are not ?using gradient pressure why

3333


from where i get mortar pastle for glass bottle crush? it's required for testing of it?

2224


why we are using hexane in calibration of number of drop per mL

1662


How can we calculate offset value pH measurment

1462


all types of questions asked at the cipla interview

4632


What is shaking level in GC?

738


how to set sample and standard concentration in RS method?

840


why we use Dichlorobenzene.nitrobezine.t-butyldi sulhate.for calibration of gc Head space

2203