what is the real reason than natural draught cooling towers are always in hyperbolic shape
Answer Posted / keyur donga
For Creating the venturi effect and natural draft & work as a nozzle and diffuser for steam outlet and more heat transfer take place in cooling tower, so thats the reason natural draft cooling tower is in hyperbolic shape
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
what does mean by kva rating
What is difference between secondary Air & Tertiary Air and Their use.?
What is LB-SR.
By any way can we increase the B check hours from 300 to 500
How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.
Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?
can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525
why is the in steam turbine axial displacement of active side thrust pad is positive and non active side thrust pad is negative.
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon
Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.
How to calculate power press toneage
why airtel use + 24 volts and other operators use -48 volt
How do you consider that you can improve and what assistance do you need to achieve this
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.