what is the exact diff betwen the uniformity of weight &
uniformity of content?
Answer Posted / nimittank
Uniformity of Weight is carried out to get information whether the weight of individual units are having uniform weight or not. It is also used to calculate content uniformity when the from the assay results only when the dosage form which are having Active Pharmaceutical Ingredient more than 25 % of the excipient used in formulation. This is carried out during chemical analysis.
Uniformity of Content is carried out to check the uniform distribution of the Active Pharmaceutical Ingredient of 10 units from the randomly selected units. This test is carried out mainly when the API content is less than 25 % of Total Formulation. This is carried out on Instrumental Analysis ( HPLC ).
Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What skills would you look for while hiring a pharmaceutical representative?
how to make Enrofloxacin 20% solution & whats remedy to avoid crystal formation in this batch after 15 -20days? Please anybody assist in it
what are the most common infectious diseases a pharmacist sees? Do pharmacists routinly encounter antibiotic resistent in some of the infectious agents that patients have contacted? if so which onces?
hi i have done my b pharma and now i am working as a managing director in my own manufacturing unit is there any scope overthere 4 me
What are the common indications for prescribing Alprazolam? How does it differ from other medications used to treat anxiety?
How would you stay updated with the latest guidelines and recommendations for prescribing medications like Alprazolam in your practice?
How to check the integrity of Sieve, Screen, FBD Bag?
Can you explain the pharmacological mechanism of Alprazolam and how it interacts with the central nervous system?
is there any entrance exam conducted for the post of drug inspector and what is the usual time
how quantitative stability studies are done?
which is the best pharma company u think
what type of person need for this company
what we do when calibration of any instrument is fail ?
What is difference between assay and content uniformity ?
What exepients are used in dry powder injections?