What is OLTC in transformers and what is its function?
Answer Posted / tanmoy
OLTC is an Onload Tapchanger. It is connected through the tapping leads to the regulating winding of the transformer.Most of the transformers have OLTC connected to the Primary winding of the transformer. However, there are tapchangers which supports bi-directional power flow, hence can operate in both primary/secondary windings of the same transformer depending on the direction of power flow. For an instance,if a step-down transformer being used as step-up transformer then based on the direction of power flow, the OLTC connected previously to the primary winding of the transformer (step-up case) will be now connected to secondary winding(step down).
Hence, it will be viable that we use the phrase regulating winding of the transformer instead of using primary & secondary winding of the transformer.
Nevertheless, the voltage regulation is achieved by utilizing desired number of turns of transformer windings segregated in taps, which can be selected as per need of required voltage.
Tapping arrangement is further bifurcated into different schemes..viz., Linear, Reversing & Coarse-Fine.
Hope, you will find the above explanation in order. Request for feedback folks.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is the difference IN MCCB's between thermal magnetic and electronic tripping system ?
if we give 60 hz single phase supply to the transformer used in europe , than what will happen
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
can anyone explain the star-delta motor control wiring ,which wire go where and how they operate?
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.
How to know Resistance and Reactance value of main and aux winding of single phase capacitor start capacitor run induction motor to find capacitor value?
hi this is hema can anyone mail me previous years questions for the APPSC-A.E.E (in electrical stream.) ......thank u.
electrical
What is the formula for selecting the cabels according to load? How to calculate what sq.mm cabel to be used?
How to select a transformer group to connect a 0,433 KV generation with 33 KV grid in bi directional flow of current
please describe the Transformer setting, Motor setting, I/C setting, Tie setting
how current is reverse from its normal direction during the fault?
what is the relationship between current&voltage in practical purpose ?
why connecting surge unit in contactor coil
Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.