Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to reduce the co level in your 1000kva dg set side?

Answer Posted / satya dev

There are so many factors to emmiring the CO of generator set eg. poor filterarion of fuel,rocker leaver arm are not adjuested properly that is why fuel not consuming properly. fuel quality may not be good.

So you need to set all the parameters and operate the genetaror atleast 80% load to reduce the CO level.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

is it possible to turn on the single phase star delta on delay timer using 24 v dc ?

2058


How to measure current and voltage in an ELV circuit

4170


What are the basic elements used for modeling mechanical translational system?

1132


how to compute kAIC?  with formulas...

4246


Earth has zero potential then what would be the neutral potential ?

1435


How to calculate main incomer rating of APFC Panel ? Let's say i want to find main incomer for 11kV, 1000kVAR Panel.

1959


Why auxiliary transformers are not connected in parallel in primary stations?

1435


May I know how much values to be set for earth fault, over current and short circuit values at 11kv side? I have 11kv van 1250amps rating. Present it's taking load 80amps?

1500


Why can't we take NO LOAD TRIAL of motors having V1 mounting??

1933


describe the constructional features of an auto transformer and its principle operation

2365


- two pumps must work with them at the same time but if the first pump start the second pump  must delayed for some time to start  also , with motor rated power = 90 KW and rated voltage = 380 V and rated power factor = 0.85 lag please draw the power and control circuit for it and determine all circuit components parameters that you use it

2752


Please clarify 1. Icw: rated short circuit working withstand capacity 2. Icu: Rated ultimate breaking capacity 3. Ics: Rated service short circut withstand capacity 4. other specification of ACB

2745


What is lc oscillator?

1196


H.t motor 6600 volt to same motor lt supply 440volt supply applyed to h.t motor to effect....

1900


Explain the working principle of Synchronous Generator and Assynchronous generator?

2254