Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How a synchronous generator practically work? what is the
function of avr(automatic voltage regulator)in synchronous
generator?how the connection of avr to the generator made
practically?please give me the answer.

Answer Posted / akash mishra ( steam turbine,

Modern day practice is to use brushless excitation system. In this system Alternator, Main Exciter and PMG are mounted at the same shaft. PMG is a permanent magnet generator which generates 3 phase voltage of 150-250 volts at 100-200 HZ ( example TPDS Alternator PMG 150 Hz, Andritz Alternator PMG 100 HZ). This output voltage of PMG is feed to AVR and it act as a input power for thyristor bridge rectifer inside it. AVR is a microcontroller based device which senses terminal voltage of alternator with the help of PT ( generally 11000/110 volts PH-PH) AVR decides the firing angle of thyristor bridge depending upon the error signal generated (Setpoint minus actual value). This controlled DC output of AVR is feed to exciter field winding (stationary) which in turn induces voltage in exciter armature. The output voltage of exciter armature is connected to generator main field winding via Rotating rectifier assembly ( RRA Diode bridge). Hence the main field winding current is controlled in a closed loop manner. AVR continuously monitors terminal voltage of alternator and always tries to maintain the setpoint ( 11KV) equal to actual value. In this way AVR maintains the terminal voltage of alternator at a fixed value irrespective of variation of loads.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Difference between transition and diffusion capacitance

2921


What is EHT tariff or Power factor Tariff ????

2294


in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply

2042


Phase control and integral control are used for?

2253


what is the acceptable value of TAN DELTA and dissipation factor for 11kV, 1.75HP Motor?.

4113


What is the effect on power factor, shown by a trivector meter; incase of reverse phase sequence. If the power factor of a system is lag what meter will show in case of reverse phase sequence connected to the meter. and What in case of lead.

2258


Can we use 230VAC, 63A MCB for 120VAC, 63A supplied heaters load?

1429


What must be the minimum distance maintained between 2 Generators as per International standards?

2044


If short circuit ratio is high is it bad or good for a machine then tell the reason...

1982


please give me solution to rectify the emi(electromagnetic interference)

1847


What is marx circuit?

1073


what is a bus riser in power system and why it is used

46004


What is deference between MCB & MCCB & ISOLATOR

2047


How the over load setting for HT Motors calculated-provided in Numerical Relay

1735


Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?

1997