Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why ct secondary is not kept open while primary charged. Answer in terms of ct parameters.

Answer Posted / gautam

 if we open circuit the secondary terminal current across this terminal falls to zero. as VI is constant for a Xmer voltage across secondary side increase drasticly,which results electrical breakdown across secondary.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to assume answer to electrical questions

1525


what is load despatching

2205


What are the main parts of central chiller plant? Explain the function of each stage.

4797


how to select the automotive wire size by mathematical calculation. for xenon headlamp with ballast. the ballast given data voltage 10-17v,current permenant 6amp, run up phase is 15amp, peak at swicth on max 400micro sec is 40amp.the sum of cable resistance is 150mohm.please provide referenc document if any for relating the peak at switch on current,time & wire wire size

2372


what happen if the load connected to the induction motor is taken away? the same question for synchoronous generator in synch i think that the the exitation voltage will appear on the terminal only if so plz answer me

1996


why actual valve timing diagram is different than ideal valve timing digram of a 4 stroke engine?

5560


List of equipments required foe industrial repair lab.

1885


Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this

1734


In Electrical 'Single Line Diagram' cable nomenclature shows "2 X 1C X 630sq.mm to be provided for one incomer. The question is how many cable to be proved for one Incomer.

1748


explain with diagram how to protect transformers and substations from over current with help of CT's?

1946


why we testing the core balance of the transformer before comissioning?

2164


Which type of DG need Netral Earthing?

5288


How to calculate the Efficiency of Chiller

3338


1. A bomber drops a bomb from an aircraft flying at 2000 km/hr. at an altitude of 7km. The speed at which the bomb will strike the earth would be

1901


what are the parameters plays a major role in Potential transformer Burden calculation??

2186