HOW TO CALCULATE EACH PHASE CURRENT WHILE A MOTOR CONNECTED
TO STAR- DELTA STARTER?

Answer Posted / hanook

Simply by using TONG TESTER..

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the reason that the humming sound is coming from the induction furnace panel?

2085


why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.

1661


What are diffrent type of road taxes?

1478


What is “pu” in electrical engineering?

675


what is the soft starter principle? how is connection diagram? what is the procedure for checking the connection?

1723






When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

1682


I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.

1382


How can we calculate the KVA rating of a Distribution transformer from its core details?

1608


Write the current equation in series RLC circuits.

643


Why is a synchronous motor always star connected??

2117


why in the three pin plug all 3 pins are cutted ?

1539


Starting Time of LT & HT Motor

1490


Explain about 3 phase motor fault current calculation with examples?

2416


what is cathodic protaction?

1497


Why the magneti fields are not passes from southpole to north pole

1650