Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In HPLC when we use Isocratic method, Gradient method in
hplc?

Answer Posted / dkiran

in the gradient composition method , impuries give high responses upon changing the concentration of mobile phase

Is This Answer Correct ?    1 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why holium oxide prepared in 10% HCLO4 SOLUTION

1448


What is the requirement for brazil in the analytical method vslidation comparr to ich?

759


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3165


why should we perform dissolution PVT calibration only by UV spectrometer, not by HPLC ?

1702


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1587


What is mean by PDR?

934


Colorimtry

1647


What is the difference between purge septum flow and column flow in gas chromatography?

2568


How do we fix the sample concentaryion in hplc method development?

1131


Why Ethanol is Used for Standardization of GC Head space?

4223


What is control room temperature and which guide line says?

1624


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3532


for inorganic molecules require to do RS, Assay and disso?

727


in which situation ion pair agent require to use?

724


how can give the expiry period and restadardisation of volumetric solution

2582