What are the protections required in the main lt panel
which is connected to the transformer.
Answer Posted / karthick
1) first thing panel body earthing (it according to the ip/op)
2) proper earthing pit,strips and size
3) proper place and proper air flow ,exiting of air
4) stranded size of panel fabrication and bus bar impulse testing , high voltage testing
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Merits & Demarits of Oil circuit & Air circuit breakers ?
What is evaporator & condencer & compressor
current transformer balance the power level on both sides. e.g in case of step up, at secondary side voltage rise but current decrease and vice versa in case of step down transformer. but how this power level remains same in case of current transformer and voltage transformer
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
What is the difference between AC and DC injection methods for rotor earth fault protection
how to get electrical supervisor competency certificate in gujarat. i did 3 year diploma in electrical
1. Why is the speed of shunt motor practically constant? 2. Why dc series motor use to start with heavy loads? 3. advantages & disadvantages of separately excited generator over self excited generator?
How to maintain ac plant?
Factory acceptance test. FAT. For 132 kv transmisstion towers what is that meaning and what are the tests commonly companies perform now days.
what is conductor constant of raccun conductor
dg earth connect only in the amf panel or not why
in parallel operation of power transformer why the distance between power transformer and capacitor bank feeder is necessary to know
hi I have done 3 yrs diploma in electrical engg after 10+2. I have 16 years of work experience into design proposals sales and engg application development in LV/MV swithcgear and sub station automation field. I want to apply for immigration to new zealand but I am not sure whether I qualify or not since I dont have a degree. Can anyone advice? Thanks Riz
how to select the isolation tranformer for siemens 802dsl cnotroller
What is the importance of earthing?