Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between kf  and LOD

Answer Posted / rahul shukla

in LOD we identify the total volatile substances including water in a sample but in Karlfisher we identify only water content in the sample but not remaining volatile substances that is deffrence between LOD& KF

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if your impurity coeluting with each other in that situation how require to set specification? is it acceptable?

972


Qc interview questions

1734


What is the acceptance criteria for moisture balance when calibrated with sodium sulfate

2035


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3533


IS THERE ANY EQUIPMENT TO CHECK AND CALCULATE THE POLARITY OF A LIQUID?

2448


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3660


In Dissolution Test why limit is define Q+5% what is the role of +5%.

3094


in each media we require to use SLS? how to proceed?

774


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

3859


In Assy by potentio metry titration method how select MET U ,DET U, SET U,

2155


WHICH STANDARD WE USE IN SILICA ANALYSIS IN SILICA-GEL METHOD FOR SOLID SAMPLE

2126


How to calculate coreletion coefficient

1704


Which parameters require to do in tech transfer?

751


In performance Check of GC Why Hexadecane Peak is Considered 

3033


if instrument calibration fails then what require to do?

973