Answer Posted / mohammad anwar
input 4-20 ma
output 3-15 psi
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
Can anyone send most commonly asked interview question in Oil & Gas industry
Describe the functions of the Operator Interface including the considerations related to alarming and display layout/configuration/layers.
How digital input and digital output 's are working in dcs
What is the use of temperature compensation?
What is critcal speed. what is resonant frequency. why we want to cross crtcal speed on higher RPM (early).
Explain signal isolator
flow transmeter accuracy 0.075% of full scale & find ucertainty is 0.025 % so what is maximum limit band of uncertainty
Draw block digram for well head from well to shipping pump?
the 3 most common transmitter protocol being in refinery or qatar gas and aramco.
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
what is span value and zero ? and how set ?
Im having problems with interfase betwen SPI v7.0 and SPPID v5.05. Previous versions of Intools shoul be fixed with SPPIDproj.ocx file. It was necessary to replace this file with one that allows the connection between different versions of SPPID. It is necessary in the current version to do the same?Thanks
What is first echo & echo window in radar type level transmitter?
1.can you use SCADA instead of DCS,DCS instead SCADA 2.Difference between DCS and PLC,can their role be reversed i.e. role interchange 3.Difference between RTU and PLC
what is insdustrial vibration.who it works. give atleast 2 types of insdustrial vibration