Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is RTCC panel and why it is required

Answer Posted / kishore kumar balligavi

RTCC Mean (REMOTE TAP CHANGER CONTROL) it use increse the voltage total 17 tap 1 tap increse the 3 or 5 volts

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is KSR type transmission tower? What is LSR type transmission tower?

5331


Pl. brief about break-down maintenance of machine tool.

1741


Bimetal strip used in overload relay what is that,which types of material used for that & percentage.

2147


Why squirrel cage motor can only use with low starting loads ?

1992


Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?

1911


we need a ntpc previous papers

1875


how to CHECK CT AND PT AT THE FAULT OCCUR IN GENERATOR RELAY PANEL .

2231


IN dc capacitive reactance is??

1342


mccb service sittings be done?

1887


How impulse levels are calculated that for 11kV impulse is 75kvp, for 24kV impulse is 125kvp ?

1948


in electrical control panel. how can i choose the cable rating. (example - 11kw motor, 18-25A mpcb}

2802


Why do power lines not short out when they fall into water?

1931


anyone please send transformer parameter design formulas & details of tap changer ? plz i have interview this week its more helpful for me ?

1820


Is it possible to implement Restricted Earth Fault protection for a transformer without neutral CT?

4240


How to calculate no of EARTH PIT? Describe the formula as per IS standard?

3727