Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

If cvt is most advance & effective(economically & stability)so why not use instead of VT(11 kv & 33 kv)?

Answer Posted / jiggykops

be cause cvt cvt used in 66kv and above because at such voltage vt s cost to high

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what maximum range of star & delta in hp or kw ?

1684


How to design the earth grid for lightning protection in an industry

4653


what is the difference between oil surge relay and buchholz relay.

7030


What should be the voltage between Neutral and Ground in secondary side of the step down transformer (230 V to 110 V) with no load condition?

2030


How much ph is maintained of water electrolyte which is used in LRS for 1200 kw slipring induction motor ?

1765


can i connect wavetrap in 2 different phase in EHV line?

1832


Please, if 1kw is equal to 1.25kva; how then do I know how many kva in 7.5kw?

1654


List examples of current sources?

1105


What is the diffrence (Technical & Construction ) between CBCT & Normal CT?

2018


Describe the colour rendering properties of i) tungsten filament lamps ii) tubular fluorescent lamp

3134


A parallel flow heat exchanger will perform better than a counter flow heat exchanger. State if the statement is true or false.

1250


What is the meaning of dedicated earthing?

2157


Inductor and capacitor........power in one phase and ...... in it another phase.

2141


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2146


What is the automatic voltage regulator with servomotor?

2032