Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to calculate the current in DG
What are the type of power pls explain with related formulas

Answer Posted / ramachandran

In dc power is equal to the product of the voltage and current (I.e., P-V*I) by using this formulae we can calculate current in dg 

Is This Answer Correct ?    2 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1 hp is equal to how much watt?

1248


what a function diesel generetaor turbo charger & turbo charger is more heated explain reason ?

2250


In CTs tan delta point should be earthed , what is the reason behind it?

3019


What should be the voltage between Neutral and Ground in secondary side of the step down transformer (230 V to 110 V) with no load condition?

2029


what is the voltages using in movie theaters??? why ??why not other??

2290


On a 3 winding transformer YNynd11, how do you apply REF protection to the Delta tertiary winding that is supplying auxiliaries to a substation?

4368


HOW TO CALCULATE HV CABLE SIZING?

3208


what is difference between elr and R eartl realy.

2628


what is the ms flat constant for calculating earth mat design calculation?

2502


I am a possesor of c licence from 1993. I forgot to renew during the year 1998. During that time I was working at TNEB to till date. Is there any possibility to get renewed? or to apply for a new one?

2036


A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2809


Logic using 1 kV or 1,1 kV grade in house wiring Low voltage cable. Explain/suggest? some use 1kV and some prefer 1.1kV grade insulation low voltage cable why??

1642


Why it need to form a capcitor when it not been in use from three or two year. Plz describe it technically.

1929


iam working in power plant. In hot places tube lights are glowing at the end portion only. what is the reason for that?

1914


How to decide CT & PT ratings for a given transmission line carrying some rated voltage?

2323