Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

in three phase 11kv transformer (11kv/433v)
input( R,Y,B) output (X,Y,Z,N) the connection as follows
1 phase R -open
2phase y connected to both R and y of input]
3phase B- B
what is the output voltage X to N ,Y to N , Z to N


Answer Posted / ananyomous

230v

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Do inductive loads have distorted current waveforms ?

1881


If only R Phase is connected in 2 pole elcb, n is not connected than it will work or not in ground fault.

1401


why we use four type of phase angle difference between pimary & secondry winding of a transformer & where we use them?

2052


how to caculate cable size for diff types of loads? if anyone know the calculating procedure please tell me

1402


the grid connection required for a 50 MegaWatt fotovoltaic powerplant is higher or lower than 35kv (high or medium tension)?

1816


it is possible to rotate the DG engine dc starter with wrong polarity connections? why?

2221


EXPLAIN USE OF ROCKING ARRANGEMENT IN ELECTRIC HEATING?

1893


What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer

2336


Sir 33kva 2 transformer load 900 amp calc 1800 amp mana jayega

1789


what is is the potential diffrence between two phase ?

6307


Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir

1882


Vaccum circuit breaker

1341


why single CT used in DOL starter power circuit?

2473


what is working process of star delta controlling circuit ?

1842


how to electronic energy metter failed in electomagnectic fild passing in the metter and which thing to defect more on metter.

1938