Why 36 KV LA is used in 33 KV Line and 9 KV LA is Used in
11 KV Line
Answer Posted / prakasa rao
lightning arestor connected to phase to neutral not line to line.
Is This Answer Correct ? | 2 Yes | 4 No |
Post New Answer View All Answers
what is die electric strnth of transformer ?
(In MEP services) HVAC in AC Plant room what else can we provide if the chiller is not considered?
what purpose to use excaiter in DG.?
What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.
What is the reason of polyphase induction motor tripping suddenly on high current during running at 70% laod? Motor IR , winding resistance & inductance balance. Motor no load current is balance and ok as per mgfr. data.
what is the function of gss in the dg set.
what is the ground fault relay,which purpose it will be use,clearly tell me plz
How many types of losses occur in a transformer?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
how to synchronize 3 phase slip ring induction motors of different ratings.
In the N-series schneider reclosers. What is the difference between current during fault time and current at tripping? This appears in the Event log in an event of a trip out.
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
if you are in a software company,then why do you want to come in a core company like sail, ntpc(where lots of trouble like tension but you have a good life in a it company) ?
how to calculate the loss tangent of electrical cables
What is the formula to calculate the rating of power cable for three phase current.