How can I communicate with an Areva MiCOM P121 relay by
RS485 port? In other word, which command can I send and
what information can I have recieved? please send some
refrences, please. thanks
Answer Posted / nur.asidik
all micom series compatible for mudbus RS485 as basic communication protocol,
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is meant by class 1 E in electrical power supply?
Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.
Pls Breifly explain about UPS (Inverter,Reserve,Rectifier,Float voltage,Boost voltage).
If we connect a motor and generator together (I mean that the generator gives the motor electricity and the motor gives the generator movement) regardless the losses. Will the generator still generate and the motor still move?
What will happen to the protection and metering, if the polarity of a single or two PT/PTs in three phase system is reversed? Please provide reference if any.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Its possible to use 3core 2R of 240 sq.mm cable for 3phases & separely 50sq.mm 3core cable fully for Neutral for connection of PCC to MCC 3ph..4wire system?
The SFC of an engine is 0.25 kg/kW hr. when the fuel used has a calorific value of 36000 kJ/kg. the thermal efficiency of the engine is
how to calculate short circuit current for the busbar
From past few months I am getting lagging pf even though sufficient capacitors used in circuit. Where is the problem pls answer
how to calculate the settings for shaft ct protn in hydro generators
relation between power station capacity and voltage level?
i have attended the interview on 4th June,08 at Kolkata in IOCL, can anybody tell me what is its result
How many VSC based HVDC are there in India and the world
How many types of oil using in H/T & L/T Oil Circuit Breakers. need Explenation ?