What is mean CT Saturation? How to calculate?
Answer Posted / nur.asidik
according to me, almost answers are correct,
in my understanding CT saturation is expressed by knee point voltage for class X, class 5P or 10P CT.
| Is This Answer Correct ? | 3 Yes | 5 No |
Post New Answer View All Answers
As an electrical engineer what are the responsibilities which i can hold in TCS?
What happens if the negative to earth voltage is greater than positive to earth voltage in the battery of substation?
what are the advantages and disadvantages of speed control of 3 phase induction motor by varying frequency explain with drawing
impliment (AB)`+C to transistor representation
In constant power region of 3-phase IM torque-speed characteristics, if frequency increases slip A does not alter B decreases C increases D none of above
Dear Sir/Madam, I have one questions we have three steam turbines and one Gas turbine and our industry linked with the public network, we have protection system one of the protection is reverse power we can export just four MW only i would like to ask about how to calculate the reverse power. Thank you in advance best regards
7- What is the Dissipation Factor and the difference between it and Insulation Resistance Test? 8- What is the task (function) of DC and AC reactors in power plant? 9- What is the task (function) of (open delta with earthed) in some types in transformers? 10- What is the base of the selection of the vector group in transformers? 11- What is the zig-zag transformer and its function by drawing in large detail? 12- What is the polarity ? 13- Why we make short between phase(R) in high side and phase (r) in low side in vector group test? Where High Side ( R ,S and T ) and Low Side ( r ,s and t ). 14- What are the time on delay and time off delay? 15- What is the vector group? 15- What is the task (function) of different types of vector group such as Dyn11 , Dd0 , YNd1,……..,?
how are reversing the direction of dc motor
What will be advantage if we put some load in neutral of grounded star transformer & loadshortcircuit current,rated current of cable & MCB with example?
A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.
we are having 110 Kv,250mA Electrostatic precipitators for coal fired boilers. what will be static voltage and current after discharge and what time it will remain before earthing?
what is the easiest method of short circuit current calculation ? pls. derive with a mathematical example in real life application.
Do u know any one? how to find out in motor rated amps? formula?
how tto ingress mw in turbine explain.procedure ?
How 48-relay (incomplete sequence) functions?