Answer Posted / amit vishwakarma
Star delta starter used for squirrel cage motor,utilises the principle of reducing the starting voltage.all the six terminals( each of two) of 3 phase induction motor are brought to the starter ......
In fact start delta starter is simply a two way switch. The method is based upon the principle that with 3- winding connect in star, the voltage across each winding is 1/√3..i.e.57.7% of the line to line voltage whereas, the same winding connected in delta will have full line to line voltage across each.
The star delta starter connects three stator winding in star across the rate supply voltage at the starting instant. After the motor attain speed, the same winding through a change over switch are connected in delta across the same supply voltage..
| Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
I AM FROM ELECTRICAL ENGINEERING ? I AM ASPIRING FOR "BHEL".HOW I HAVE TO PREPARE .ON WHICH TOPICS TO BE CONCENTRATE MORE.PLEASE GIVE FULL DETAILS OF WRITTEN EXAM.
Can any one know what are the symbols at the down (below) the analog ammeter??? there are 4 symbols which are they ?????
what is meant by surge? what we called for high currents?
If a shunt Dynamo has induced emf 100V and 0.4 ohm resistance and battery of accumulator of open circuit emf 110V and 0.5 Ohm resistance are in parallel what is common terminal potential difference?
how can maintaince the acb contactor moveing and fixing kit
any one please tell taht what type questions will be asked in BHEL interview, i am having interview on 24th Dec, please send this to mail pradeepsistam@yahoo.co.in
Where voltage are high and current to be interrupted is low the breaker preferred is:
why are the maintaine power factor and how can this control and this is how work.
What do you mean by a voltage transformer?
what is per unit calculation?looking for simple and strong explanation thk u
What is grid collapse? what is the reason for it?
what is the function of gss in the dg set.
what is the max. acceptable leakage current in 33kv bus bar
How to detect voltage vector shifting in interconnection protection.
A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.