why all selected supply voltages are multiple of
11.i.e440,11 kv,33 kv,66 kv,110 kv etc

Answer Posted / dhaval shah

The miss concept is Line voltage is in multiple of 11 due to Form Factor. The form factor of an alternating current waveform (signal) is the ratio of the RMS (Root Mean Square) value to the average value (mathematical mean of absolute values of all points on the waveform). In case of a sinusoidal wave, the form factor is 1.11.
The Main reason is something historical. In olden days when the electricity becomes popular, the people had a misconception that in the transmission line there would be a voltage loss of around 10%. So in order to get 100 at the load point they started sending 110 from supply side. This is the reason. It has nothing to do with form factor (1.11).
Nowadays that thought has changed and we are using 400 V instead of 440 V, or 230 V instead of 220 V.
Also alternators are now available with terminal voltages from 10.5 kV to 15.5 kV so generation in multiples of 11 does not arise. Now a days when, we have voltage correction systems, power factor improving capacitors, which can boost/correct voltage to desired level, we are using the exact voltages like 400KV in spite of 444KV

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT HAPPENED DC SERIES MOTOR FIELD WINDING OPEN. CAN POSSIBLE.

3351


if we have 320KVA Genset kindly advice how much load we can put it.

1135


How PSV sizing being done

1932


What is the capacity of the Fastners 12mm?

1990


For group 1 , 2 whather i have to prepare my technical or general studies etc? and im graduate in ee engg. for wht posts im eligible for? please tell me!

1836






A logic circuit that provides a HIGH output if one input or the other input, but not both, is HIGH, is a(n)?

771


what is the difference b/w ATS and HTS?

1820


what is the criterion for selecting vector group of Transformers ? i mean how to decide vector group of Generator transformer, substation trasformer and transformer at consumer end

1885


when we gave dc supply to 220v dc motor its rpm is 1200. then we gave 180v. how many rpm of its motor. gave answer with calculation at my ID.... ravizak@ymail.com

1982


Is there chopping current in resistive circuit

1617


what is the differebt between ac and dc fuse?

1962


Name one of major transformer company in KSA ?

858


How should i design a 1ph & 3 ph transformer. Kindly let meknow all steps and formulaes related to design from scratch.

1700


what is the difference between vector scale and vector diagram?

3919


what is the IEC standard for Power Cable installation in onshore (like in direct buried ground or above groung)

2254