Why attemperation is required in HRSG in a combined cycle
power plant?

Answer Posted / keyur donga

when the main steam temprature is goes high At varying load of the HRSG At this this time We maintain the Steam temp by using attempration in HRSG.

Is This Answer Correct ?    13 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

operation

1476


explain how the third harmonic content of the magnetising current affects transformer design

2876


im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much

1591


Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon

1999


How do you consider that you can improve and what assistance do you need to achieve this

1415






why is the in steam turbine axial displacement of active side thrust pad is positive and non active side thrust pad is negative.

2871


Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.

1964


what is the basic use of power plant in equipment

1312


what does mean by kva rating

1080


can dp type level transmitter work in under vaccum condition

1629


What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

2029


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

618


How to calculate power press toneage

1649


We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?

1530


how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?

1332