Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we compare unequal concentrated solutions in heavy metals test. For example comparing the test solution with 1 ppm lead standard and telling it's less than 20ppm?

Answer Posted / ch jagan

sorry,the question you have asked is wrong.we compare the sample solution with the standard solution of the concentration which is equal to our specification limit.e.g.specification limit 1.Less than 20 ppm,2.not more than 10 ppm in this both cases we will prepare 20 ppm and 10 ppm standards respectively.thank you

Is This Answer Correct ?    6 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the principle of Thermal conductivity detector and FID?

2726


How we performed the force degradation for drug substance, is any specific guideline is available for each parameter(Acidic, basic, oxidation,heat)? what conditions you mentained for above parameters.

2304


analytical method validation require to with respect to release specification or shelf life specification?

791


what is the principle of UV Vis spectroscopy, AAS, ICP OES,ICPAES, ICP-MS and FTIR

9246


What is the calibration of uv process and preparation

1997


in dissolution if one bowl got 70 percent 2nd bowl got 80 percent and 3rd bowl got 90 percent then how proceed?

750


if you get peak in blank then what require to do?

974


How require to perform linearity as per ANVISA? What are the acceptance criteria?

1334


In the isomers,enantiomers give the only physical properties present such that no chemical properties present.

2221


what is different when impergnated silica plates are used in separation of azo dyes using column chromatography?

2024


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3175


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

3860


WHAT IS THE PURPOSE WE USE HCL, CHOPPER, BURNER, MONOCHROMATOR in AAS? PLEASE EXPLAIN BRIEFLY

2607


While performing TOC sst analysis Zero shift disabled & sample analysis zero shift enabled why?

2862


Why sometime potassium ortho phosphate mix with acetone use for sample preparation for hplc

1465