Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

0.1 atom gram of the unknown element( X)reacts with 2.4 gram
of O2 to produce the oxid product . can you tell us, what is
the oxid formula ? a) XO b)X2O3 c)XO2 D) X2O4

Answer Posted / santhosh reddy

X2O3

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

AT WHAT CONDITIONS WILL YOU ANALYSE A SAMPLE,WHICH ARE PRESERVED AT OTHER THAN THE AMBIENT CONDITIONS?(ie COLD STORAGE SAMPLES BELOW 20* CENTIGRADE?

2016


why we should take dst factor for below 1%moisture samples

2616


what is diffrence between specificity and selecivity?

715


How to set analyticl specification for combination products?

689


For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?

2264


what is the acceptance criteria for enteric coated tablets in 0.1n hcl validation in each parameter?

836


can we use the same detector in HPLC as well GC and what could be the differences we can find in the final chromato graph in any aspects?

2127


In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )

3427


Why we use potassium dichromate in uv calibration Exact reason behind it??

1190


calibrtion procedue of LC-MS

2669


how require to set assay concentration for standard and sample?

866


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1549


Why a1% value is used for some product ? What is the criteria for selection a1% value ?

2293


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1807


How to decide assay range for non pharmacopeial API analysis by HPLC? Could you give me any reference for same e.g Guidelines or Paper publications?

3304