Answer Posted / satheesh kumar g
Ground or earth in a mains (AC power) electrical wiring
system is a conductor that provides a low impedance path to
the earth to prevent hazardous voltages from appearing on
equipment and "earth" are used synonymously here). Normally a grounding conductor does not carry current.
Neutral is a circuit conductor (that carries current in
normal operation), which is connected to earth (or ground)
generally at the service panel with the main disconnecting
switch or breaker. the neutral is always connected to earth at the binging of a distribution transformer for avoiding the un balanced condition.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.
what are the application of over current relay?
what is the size of ht cable of 33kv ht line and transformers ratings are 1 Mva and 5mva.please send formula also.
how we calculate torque ? how we improve it ?where torque will either motor or generator ?
Which are resistive loads & which one are inductive loads : Refrigerator, Split air conditioner, ceiling fans, well pump, fluoresecent bulbs, T.V, CRT Monitors, Adsl Routers, C.P.U, Printers, Deep Freezers, Speakers, DVD Players, Microwave oven etc. ? Output Power for these Appliances Would be same like this : P = V * A * P.F Or would be changed ? thanks
What is instrumental error?
What is the equivalent circuit of a transformer and its vector diagram?
How to do stting of vl250 siemens MCCB
How to measure the Harmonic Distortion of UPS ie THD?
An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
Define newton's law of viscosity.
What is Percentage impedence of a transformer? why it is expressed at a percentage? what is the importance of percentage impedence in case of a transformer?
What is sink and source?
what is the ground fault relay,which purpose it will be use,clearly tell me plz