Answer Posted / ayaz
there are two type of vibration measuring
1 seismic vibration measuring : in seismic vibration is measure the device body monitoring structure
2 prob vibration : prob vibration is measure the device shaft coupling etc
there are two type of prob axial and radial axial use in parallel of shaft and radial use center of the shaft
Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
what is difference between fork type and capacitance type level switch. where it is using
Why 4-20 amps is being used in instruments? Why cant we use any other range instead of 4-20 amps? Why only 4 amps is taken as lower limit and why 20 amps is taken as the higher limit?
How to convert Differential pressure to flow in TPH
what is intrinscily safe system and where we use?
PLEASE PROVIDE SAMPLES OF CHEVRON SKILL TESTS
If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?
what is the difference between -24 : +24 & 0:24 and where it use?
Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.
How can measure flow in oil line?which type of transmitter is generally used?
Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
when placing a vent or drain hole on an orifice plate should you measure from the center of the bore up or down for the vent placement?
Hi Friends i need Electronics&Instrumentation Engg question papers for BARC written test by coming 20th May 2008 pls post ur use full info to kkumarei@gmail.com. Or for suggestions pls give one missed call to 9962122264
what is function of SCADA , and how is it work, explain with difination
Good evening all I need a small favour regarding reliance paper i wanna probable sample papers(e&i) of reliance. if any of u have any idea about dis then plz mail me back.i belongs to electronics and instrumentation engg.so i need e&i papers. thanking u....
god evening sir i am studying m.sc(tech)electronics &instrumention.am i elegible to all industies