why we are giving negative supply for vibration sensors?
Answer Posted / mohammad javed
Don Bentley uses the PNP transistor which works on negative bias voltage. That why a negative voltage is used in vibration sensors. It is the circuit design which require negative voltage.
| Is This Answer Correct ? | 3 Yes | 4 No |
Post New Answer View All Answers
send me model hpcl questions pleas..........my mail id mohideen.dharvesh@gmail.com
Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .
plz tell me clearly about PID.."when v have to change I value,D value,GAIN??
what is vibration a part of proceess variable? if vibration is a part variables then how we minimize the actual vibration on machine on load,? vision of instrumentation contrl plz ans me IPGDL interview question
need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate
What are the type of bonnets in the control valves?
For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?
Sir, I am working as a Instrument Engineer in Grasim Industries. Can any body provide question answer for interview purpose
hi! i want to know about mpse exam.
How ejector(or)evactor air pump is working in thermal power plant?
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
How we can check the 2 wire proxy switch? & how it is connected to DI MODULE OF PLC?
what is the difference between profibus and controlnet networking.
why orfice is not used for main steam flow calculation
the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove